Mastering the eco cute! (hen introduction)
Home – Garden & Home Improvement | Jodee Metty | 5 views
If you can understand already a little by yourself, after also what is thought often. |
“As for the thing of echo cute you do not understand well.If as for selection of the type that the designer entrust, the builder entrust”, it is good, whether truly the hot water not being cut off, only the viewpoint of the catalog you understand, although you can research more by your, with you have not thought?
This time, “it masters echo cute”, is.When the “introduction compilation” “it starts using, dividing into 2 times of the compilation,” we send.
The a, the catalog which is obtained in one hand, this article it is perusal!
First verification of capacity
The specifications of echo cute first are from tank capacity.Capacity mainly, is 300L, 370L and 460L, means to choose according to the number of people of the family.Standard is sort under.
Standard (from the Tokyo Electric Power home page) of echo cute capacity choosing |
In case of the large family 6 or more, the manufacturer is limited to Mitsubishi or Toshiba, but because there is 550L and 560L type, please choose that. (However the Toshiba 560L type the refrigerant not to be CO2, outside the object of the echo cute subsidy)
However it should note size of the bathtub.If it is the unit bath and the bathtub to 300L, with according to the catalog of echo cute there is no problem.So, the large-sized bathtub which exceeds that when thinking note is necessary.also should consider the capacity of the larger eco cute is a good.
using the hot water of your own home is, i wonder often compared with elsewhere? i think some such anxiety. about from the recommended value to appear in catalogs and web site, let’s go ahead and another.
first, from the question which tends to be misunderstood.
300Lit was covered in hot water may run out of capacity bathing once you have selected the eco cute?
there is no such a thing.
in the tank is approximately90 boiling at high temperatures has raised. i have been in hot water set temperature while mixing water at the outlet it.
that is, in the tank90 of hot water42 it is a point or something equivalent to l of hot water.
i found a number that be an indicator in the instruction manual of daikin.
in the specific example of eco cute is appropriate or what l! · · · >next page
considered in specific cases
the following table was out in the instruction manual of daikin. ability to drive almost any manufacturer is the same, assumes a concrete statue family uses this table, let’s consider what a reasonable ecocute of what l.
from the instruction manual of daikin eco cute |
how to read this table
extra level4 : at the time of operation was raised up to boiling day and night42 the amount of hot water can be used in
only midnight : the amount of boiling hot water only when the increase during those hours at night and cheaper electricity bills
310Lin tank, if you were up to summer6double1850Lof hot water (42 ) you can see, the ability to use. but, hot water can be used in winter and summer will differ.
310Lof type extra level4 in, summer1850Lbut winter is1100Land, quite different.
hot water is a different reason for the outlet temperature of the water to mix different, for details if you started using hen in.
(in this table the interim period (spring and fall) of hot water is omitted.. )
and hot water usage of each home is, you have roughly determined under the following conditions.
(bathtub) catalog value (filled with water) of8assignment
unit bus standard (the plane of the inner dimensions50cm×100cmabout) if the200L
(shower) about80L/people (per capita7~8as minute)
(warm bath) about90L/time (daikin’s manual eco cute)
(kitchen sink) about30L/people (winter only)
now, why it has been found how much hot water usage of the standard, is so can be calculated according to the circumstances of your own home.
in the specific example simulation
when filled with water360Lin the bathtub is spacious? |
4family, of loose360Lsuppose that you plan a tub of. the people use a somewhat larger and everyone will use the shower. bathing time of a continuous family are concentrated2the insulation of time and.
(bathtub) 360L×0.8=288L
(shower) 80L×3people+160L×1people=400L
(heat insulation) 90L×2time=180L
(kitchen sink) 30L×4people=120L (winter only)
————————————————————————
total 868L (winter988L) will be.
that first summer868Lif the usage of, can cover only cheaper electricity at night370Llet’s select the type of over. in winter988Lso, 370L, 460Lin any only at night in not afford, extra mode must be the. this extra because the mode boils up time of the day, means that you become more expensive than the summer.
actually switching this mode random is it you do it automatically by the function, the good news is that eco cute. (for more information next time)
calculate the amount of hot water use is assumed, see the table above against. 370Land460Lit knows that driving is not so different from the way, cheap generation equipment370Lwill be called but they look good in.
table will be based on the specific examples cited in this way is intended daikin, maximum operating capacity is almost the same with each manufacturer. material would be helpful * i think.
is there a family plan will increase after, what tends to decrease in children, such as independent, please decide to fit the style of each home, such as.
*) if there is a material similar to each manufacturer’s catalog, please refer to there.
the sound is also extremely water pressure and further! · · · >next page
check the water pressure
water pressure is more important! |
this is because electric water heater up to maximum pressure85kPaabout, complained that the weak water pressure could easily rise. but, eco cute technology has advanced, 170~190kPahave become a standard is. still, how to feel the pressure because there are individual differences, to check the water pressure in the all-electric facilities and experience is better.
eco cute is the ground body, the bath is2if the floor, 170~190kPatoo late, even models. but3i think that in some cases on the ground floor bath. in that case1the price is up about 30% of body280kPa~320 kPaof powerful high-pressure type from matsushita is, water pressure of water as it becomes pressure of eco cute “direct pressure system” has come out from hitachi is. please choose a model such.
even those that are interested in massage shower280kPaplease choose the water pressure is more than.
in that case, from hot water use will increase per unit time, 460Lbut the number of family members3~4please think for the people.
for night driving
sound operation of the outdoor unit is how much? |
sound operation of outdoor unit, also any model of any manufacturer40dBhas around. residential air conditioner outdoor unit is normal45dBfrom is around, it is the sound operation of the following. among them 38dBtype-quiet design is said, i realized that the quiet i also listen to the sound. incidentally, the same sound source of strength2even though the two3dBnot only increases. 40dBand38dBit actually is a big difference between the.
eco cute is operational since the middle of the night, if the location of the outdoor unit or residential areas and windows of my neighbor becomes close to the outdoor unit, i would rather chose a quieter design would be good.
———————————–
other, to coast harm specification salt , for cold climates cold area specification there are of eco cute.
also, if the formula floor heating hot water is said to feel the gentle warmth to the body, there is also a type that can be linked with its eco cute hot water. this floor heating linked is in relation to the capacity of the eco cute at the moment20as the largest extent is the tatami. to demand that only the living room floor heating i can afford enough. buy offers contributed to the space-saving since it does not require hot water storage tank for floor heating.
“1″of electrical energy”3″more thermal energy is obtained and is?
about the benefits of eco cute “1″of electrical energy”3″more thermal energy is obtained i think many people have noticed that has been touted as. what would be? i know somehow, specifically, do not know · · ·
why in the catalog that are represented and concrete numerical.
there is a column in the table of the heat pump unit of the equipment specification. interim period thereCOPthere is that it.
outside air temperature and the interim period (dry-bulb temperature/wet-bulb temperature) 16 /12 , water temperature17 , boiling temperature up65 that the conditions of.
COPpower consumption (kW) heating capacity per (kW) this is defined as the. will be better this value is greater efficiency. most of the latest model now4.5~5.0interim period ofCOPthey have the.
2001eco cute was at first appearance a year, this value is3. 0but it was about a little over. now technology advances, that1. 5has achieved the efficiency of the times. but, numbers such as climatic conditions change so, “1″of electrical energy”3″more thermal energy is obtained and the other thing is that.
given the law of conservation of energy, “1″the energy of the”1″that there can be no greater than or equal to. since capturing the heat in the air”1″from”3″it is equal to or greater than. what eco cute, it is not amazing.
———————————–
if you gave us to understand this article, more, considerable”extremely”people.
person in charge of design (who or construction) may falter is, is.
the next mastering the eco cute! if you started using hen is.
Incoming search terms:
- cute intro eco (1)
Additional items from "Home – Garden & Home Improvement"
- reform and open space along with the pet spend
- pink flyer every possible means to reduce the posting
- nordic landscape with a chair wrapped in warmth of wood
- IHhad better response to all-metal?
- grocer’s picture book made
- warm at any time the entire thermal storage heating and is?
- how to assess the insulation on the upscale apartment
- two-family housing is residence near also serve as a!
- basic course for a single apartment purchase (3) accumulate the down payment if the chance now!
- a large number of medium-scale apartment door appeared the number ten